Self Cleaning Strainer
video

Self Cleaning Strainer

Compressed air filters are an essential part of any compressed air system. They are used to remove any impurities that may be present in the air before it is used in any application. These impurities can include dirt, oil, water vapor or any other particles that may be present in the air. It is important to use compressed air filters to ensure that the compressed air is clean and free of any contaminants that may cause damage to equipment or lower the quality of the end product.
Send Inquiry
Product Introduction

 

Products Video

 

 

Products Description

Product Characteristics

The high-pressure, normal-temperature liquid refrigerant filtered by the drying filter enters the throttling element of the refrigeration system, which is usually a capillary tube, thermal expansion valve, or electronic expansion valve. Taking the thermal expansion valve as an example, it senses the superheat temperature of the refrigerant at the outlet of the evaporator through a temperature-sensing bulb and automatically adjusts the opening of the valve port to control the flow rate of the liquid refrigerant. When the high-pressure liquid refrigerant passes through the narrow valve port or capillary tube, it is subjected to strong throttling resistance, resulting in a sharp drop in pressure and temperature, instantly turning into low-pressure, low-temperature gas-liquid two-phase refrigerant with a temperature as low as 0-5°C. This low-temperature refrigerant mixture is then evenly sprayed into the evaporator's heat exchange tubes, and the throttling and pressure reduction process is a key step to realize the temperature drop of the refrigerant, creating the low-temperature conditions required for the compressed air to cool and dehumidify, and the precise control of the throttling component directly affects the cooling stability and dehumidification effect of the cold dryer.

 

Working Principle

The amount of water vapor in the compressed air is determined by the temperature of the compressed air: under the condition that the pressure of the compressed air is basically unchanged, reducing the temperature of the compressed air can reduce the content of water vapor in the compressed air, and the excess water vapor will condense into liquid.

Air Dryer for Compressor Refrigerated

 

Products Specification
Applicable Working Conditions

 

Max inlet temp

60°C

Pressure dew point

2℃~10℃

Environment temperature range

5°C-50°C

Cooling mode

Air-cooled

Pressure range

0.6-1.6Mpa ( 0.5-12Nm³/min )

Cryogen

0.5~2 Nm/min is R134a, 3~12Nm3/min is R410a,

0.6-1.0 Mpa (15Nm³/min and above )

15~80Nm/min is R407C, 80 Nm/min and above is R22

 

Design Working Conditions

 

Inlet air temperature

38°C

Working pressure

0.7Mpa

Ambient temperature

38℃

Cooling water temperature

≤32℃

 

 

 

Products Details

 

Air Dryer Machine

Title

Air Dryer Machine

Title

Air Dryer Machine

Title

 

 

Our Service

 

To extend the service life and maintain stable performance, we provide regular preventive maintenance service based on equipment operating hours and customer usage intensity. Professional maintenance personnel will perform periodic inspections including cleaning or replacing pre-filters and after-filters, checking refrigerant pressure and leakage, cleaning condenser fins, inspecting compressor operating current, testing automatic drain valve action, verifying evaporator cleanliness, and tightening pipeline connectors. They will eliminate hidden dangers such as dust accumulation, oil clogging, loose wiring, and poor heat dissipation in advance. A detailed maintenance report will be provided after each service, recording operating parameters, replaced parts, and next maintenance suggestions. This service effectively reduces failure rates and ensures long-term stable operation in industrial environments.

 

If you need, please feel free to contact us for more information. Email: shanli@hzsljh.com

 

FAQ

 

1. Q: Quick fix for high pressure alarm?
A: Clean condenser → check fan → lower ambient temp → reduce load.

2. Q: Quick fix for low pressure alarm?
A: Check refrigerant leakage → replace filters → adjust expansion valve.

3. Q: Quick check for no cooling?
A: Compressor running? → refrigerant pressure → heat exchanger clogged?

4. Q: Quick fix for high pressure drop?
A: Replace elements → fully open valves → check piping.

5. Q: Quick fix for freezing?
A: Stop and defrost → adjust hot gas bypass → raise low pressure.

 

Hot Tags: self cleaning strainer, China self cleaning strainer manufacturers, suppliers, factory, filter for air dryer, compressed air line filter, air compressor air filter, Air Filter, Compressed Air Desiccant Filter, Compressed Air Filter