Air Dryer Rental
Products Video
Products Description
Product Characteristics
● R22 refrigerant and tube heat exchanger are used for more than 80 cubic meters; the gas-liquid separator adopts a patented three-stage separation method of "direct collision separation, low-speed centrifugal separation and stainless steel wire mesh demisting separation", which will remove 99.9% of the liquid The moisture is separated from the cooled compressed air to prevent the secondary evaporation of moisture and ensure the low dew point quality of the finished gas;
Working Principle
The amount of water vapor in the compressed air is determined by the temperature of the compressed air: under the condition that the pressure of the compressed air is basically unchanged, reducing the temperature of the compressed air can reduce the content of water vapor in the compressed air, and the excess water vapor will condense into liquid.

Products Specification
Applicable Working Conditions
|
Max inlet temp |
60°C |
Pressure dew point |
2℃~10℃ |
|
Environment temperature range |
5°C-50°C |
Cooling mode |
Air-cooled |
|
Pressure range |
0.6-1.6Mpa ( 0.5-12Nm³/min ) |
Cryogen |
0.5~2 Nm/min is R134a, 3~12Nm3/min is R410a, |
|
0.6-1.0 Mpa (15Nm³/min and above ) |
15~80Nm/min is R407C, 80 Nm/min and above is R22 |
Design Working Conditions
|
Inlet air temperature |
38°C |
Working pressure |
0.7Mpa |
|
Ambient temperature |
38℃ |
Cooling water temperature |
≤32℃ |
Air dryer for compressor refrigerated (plate fin type)
|
Item Model |
Air capacity |
Voltage |
Fan |
Air |
N.W |
L |
W |
H |
Air volume |
|
SDLF-0.5 |
0.65 |
220 |
40 |
G1" |
34 |
400 |
560 |
730 |
410 |
|
SDLF-1 |
1.2 |
220 |
40 |
G1" |
36 |
400 |
560 |
730 |
410 |
|
SDLF-2 |
2.5 |
220 |
50 |
G1" |
45 |
520 |
640 |
890 |
820 |
|
SDLF-3 |
3.6 |
220 |
85 |
G1" |
54 |
520 |
640 |
890 |
1000 |
|
SDLF-4.5 |
5.0 |
220 |
165 |
G1-1/2" |
60 |
540 |
700 |
1000 |
1850 |
|
SDLF-6 |
6.8 |
220 |
165 |
G1-1/2" |
65 |
540 |
700 |
1000 |
1850 |
|
SDLF-8 |
8.5 |
220 |
170 |
G2" |
76 |
610 |
900 |
1070 |
3700 |
|
SDLF-10 |
10.9 |
380/220 |
150 |
G2" |
88 |
610 |
900 |
1070 |
3700 |
|
SDLF-12 |
12.8 |
380/220 |
150 |
G2" |
88 |
610 |
900 |
1070 |
3700 |
|
SDLF-15 |
16 |
380/220 |
380 |
DN65 |
255 |
1170 |
920 |
1420 |
7600 |
|
SDLF-20 |
22 |
380/220 |
380 |
DN65 |
260 |
1170 |
920 |
1420 |
7600 |
|
SDLF-25 |
26.8 |
380/220 |
460 |
DN80 |
290 |
1170 |
920 |
1420 |
9000 |
|
SDLF-30 |
32 |
380/220 |
840 |
DN80 |
350 |
1400 |
1200 |
1600 |
12500 |
|
SDLF-40 |
43.5 |
380/220 |
1100 |
DN100 |
485 |
1400 |
1200 |
1600 |
15000 |
|
SDLF-50 |
53 |
380/220 |
920 |
DN100 |
800 |
1600 |
1200 |
1600 |
18000 |
|
SDLF-60 |
67 |
380/220 |
920 |
DN125 |
1000 |
1600 |
1400 |
1650 |
18000 |
|
SDLF-80 |
90 |
380/220 |
2200 |
DN125 |
1280 |
1800 |
1500 |
1770 |
30000 |
Products Details

Title

Title

Title
Our Service
01. Pre-sale: The main responsibilities of the sales and Research Institute are to review the technical and business solutions, provide business and technical support to customers, and can accurately and timely solve all business and technical requirements before sales.
02. On sale: The main responsibilities of the Ministry of Commerce are order management and customer management. The core of order management is order delivery, business review of the scheme, and order. Timely solve the problems in the execution of the contract, and communicate with customers in order processing and delivery.
03. After-sale: Strong and perfect after-sales service network, there are 9 customer service centers in major regions of China, each center has professional service engineers, a total of more than 50 people, quickly and timely solve problems in after-sales service, such equipment start-up debugging, and troubleshooting.
If you need, please feel free to contact us for more information. Email: shanli@hzsljh.com
FAQ
1. Q: What is the function of a refrigerated air dryer?
A: To remove moisture and oil mist from compressed air, stabilize dew point, and ensure clean, dry air.
2. Q: What is the applicable pressure range?
A: Normally 0.4–1.0 MPa; rated working pressure is mostly 0.7–0.8 MPa.
3. Q: What is the required inlet air temperature?
A: Recommended ≤ 45°C; over temperature greatly reduces drying performance.
4. Q: What are the installation environment requirements?
A: Well-ventilated, dust-free, no direct sunlight; ambient temperature 5–40°C.
5. Q: Must the dryer be installed horizontally?
A: Yes, horizontal installation ensures proper drainage and refrigeration system operation.
Factory Tour



Our Advantages
1
Quality assurance
2
Price advantage
3
Factory wholesale
4
Good service
Certificate

Hot Tags: air dryer rental, China air dryer rental manufacturers, suppliers, factory, industrial refrigerated air dryer, refrigerated air dryer for industrial use, modular refrigerated air dryer, high performance refrigerated air dryer, stationary refrigerated air dryer, automatic refrigerated air dryer
Previous
Air Dryer ServiceYou Might Also Like